CAD (0)
  • Cart is empty
1 - 25 of 40 | Results Per Page | View | Unit of Measure
1 2 

Part Number

Torque

Control Input

Running Time (Motor)

Power Supply

Power Consumption

Transformer Sizing

CAD

NFB24 N4H N/A minimum 90 in·lbminimum 10 N·m N/A On/Off N/A < 75 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 6 W, 2.5 W / heater 25 W N/A 8.5 VA (class 2 power source) / heater 25 VA N/A CAD Icon (for items table)
NFB24-MFT N4H N/A minimum 90 in·lbminimum 10 N·m N/A MFT N/A 150 seconds (default), variable (40 to 220 seconds) N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 6.5 W, 3 W / heater 25 W N/A 9 VA (class 2 power source) / heater 25 VA N/A CAD Icon (for items table)
NFB24-MFT-S N4H N/A minimum 90 in·lbminimum 10 N·m N/A MFT N/A 150 seconds (default), variable (40 to 220 seconds) N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 6.5 W, 3 W / heater 25 W N/A 9 VA (class 2 power source) / heater 25 VA N/A CAD Icon (for items table)
NFB24-S N4H N/A minimum 90 in·lbminimum 10 N·m N/A On/Off N/A < 75 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 6 W, 2.5 W / heater 25 W N/A 8.5 VA (class 2 power source) / heater 25 VA N/A CAD Icon (for items table)
NFB24-SR N4H N/A minimum 90 in·lbminimum 10 N·m N/A 2-10 VDC N/A 95 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 3.5 W, 2.5 W / heater 25 W N/A 6 VA (class 2 power source) / heater 25 VA N/A CAD Icon (for items table)
NFB24-SR-S N4H N/A minimum 90 in·lbminimum 10 N·m N/A 2-10 VDC N/A 95 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 3.5 W, 2.5 W / heater 25 W N/A 6 VA (class 2 power source) / heater 25 VA N/A CAD Icon (for items table)
NFBUP N4H N/A minimum 90 in·lbminimum 10 N·m N/A On/Off N/A < 75 seconds N/A 24…240 VAC +10% / -20%, 50/60 Hz, 24…125 VDC ±10% N/A 6 W, 2.5 W / heater 25 W N/A 6 VA at 24 VAC (class 2 power source), 6.5 VA at 120 VAC, 9.5 VA at 240 VAC / heater 25 VA N/A CAD Icon (for items table)
NFBUP-S N4H N/A minimum 90 in·lbminimum 10 N·m N/A On/Off N/A < 75 seconds N/A 24…240 VAC +10% / -20%, 50/60 Hz, 24…125 VDC ±10% N/A 6 W, 2.5 W / heater 25 W N/A 6 VA at 24 VAC (class 2 power source), 6.5 VA at 120 VAC, 9.5 VA at 240 VAC / heater 25 VA N/A CAD Icon (for items table)
NFX24 N4 N/A 90 in·lb10 N·m N/A On/Off N/A < 75 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 6 W, 2.5 W N/A 8.5 VA (class 2 power source) N/A CAD Icon (for items table)
NFX24-MFT N4 N/A 90 in·lb10 N·m N/A MFT N/A 40-220 (150) seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 6.5 W, 3 W N/A 9 VA (class 2 power source) N/A CAD Icon (for items table)
NFX24-MFT-S N4 N/A 90 in·lb10 N·m N/A MFT N/A 40-220 (150) seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 6.5 W, 3 W N/A 9 VA (class 2 power source) N/A CAD Icon (for items table)
NFX24-S N4 N/A 90 in·lb10 N·m N/A On/Off N/A < 75 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 6 W, 2.5 W N/A 8.5 VA (class 2 power source) N/A CAD Icon (for items table)
NFX24-SR N4 N/A 90 in·lb10 N·m N/A 2-10 VDC N/A 95 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 3.5 W, 2.5 W N/A 6 VA (class 2 power source) N/A CAD Icon (for items table)
NFX24-SR-S N4 N/A 90 in·lb10 N·m N/A 2-10 VDC N/A 95 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 3.5 W, 2.5 W N/A 6 VA (class 2 power source) N/A CAD Icon (for items table)
NFXUP N4 N/A 90 in·lb10 N·m N/A On/Off N/A < 75 seconds N/A 24…240 VAC +10% / -20%, 50/60 Hz, 24…125 VDC ±10% N/A 6 W, 2.5 W N/A 6 VA at 24 VAC (class 2 power source), 6.5 VA at 120 VAC, 9.5 VA at 240 VAC N/A CAD Icon (for items table)
NFXUP-S N4 N/A 90 in·lb10 N·m N/A On/Off N/A < 75 seconds N/A 24…240 VAC +10% / -20%, 50/60 Hz, 24…125 VDC ±10% N/A 6 W, 2.5 W N/A 6 VA at 24 VAC (class 2 power source), 6.5 VA at 120 VAC, 9.5 VA at 240 VAC N/A CAD Icon (for items table)
NFB24 N/A minimum 90 in·lbminimum 10 N·m N/A On/Off N/A < 75 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 6 W, 2.5 W N/A 8.5 VA (class 2 power source) N/A CAD Icon (for items table)
NFB24-S N/A minimum 90 in·lbminimum 10 N·m N/A On/Off N/A < 75 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 6 W, 2.5 W N/A 8.5 VA (class 2 power source) N/A CAD Icon (for items table)
NFX24 N/A minimum 90 in·lbminimum 10 N·m N/A On/Off N/A < 75 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 6 W, 2.5 W N/A 8.5 VA (class 2 power source) N/A CAD Icon (for items table)
NFX24-S N/A minimum 90 in·lbminimum 10 N·m N/A On/Off N/A < 75 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 6 W, 2.5 W N/A 8.5 VA (class 2 power source) N/A CAD Icon (for items table)
NFBUP N/A minimum 90 in·lbminimum 10 N·m N/A On/Off N/A < 75 seconds N/A 24…240 VAC +10% / -20%, 50/60 Hz, 24…125 VDC ±10% N/A 6 W, 2.5 W N/A 6 VA at 24 VAC (class 2 power source), 6.5 VA at 120 VAC, 9.5 VA at 240 VAC N/A CAD Icon (for items table)
NFBUP-S N/A minimum 90 in·lbminimum 10 N·m N/A On/Off N/A < 75 seconds N/A 24…240 VAC +10% / -20%, 50/60 Hz, 24…125 VDC ±10% N/A 6 W, 2.5 W N/A 6 VA at 24 VAC (class 2 power source), 6.5 VA at 120 VAC, 9.5 VA at 240 VAC N/A CAD Icon (for items table)
NFXUP N/A minimum 90 in·lbminimum 10 N·m N/A On/Off N/A < 75 seconds N/A 24…240 VAC +10% / -20%, 50/60 Hz, 24…125 VDC ±10% N/A 6 W, 2.5 W N/A 6 VA at 24 VAC (class 2 power source), 6.5 VA at 120 VAC, 9.5 VA at 240 VAC N/A CAD Icon (for items table)
NFXUP-S N/A minimum 90 in·lbminimum 10 N·m N/A On/Off N/A < 75 seconds N/A 24…240 VAC +10% / -20%, 50/60 Hz, 24…125 VDC ±10% N/A 6 W, 2.5 W N/A 6 VA at 24 VAC (class 2 power source), 6.5 VA at 120 VAC, 9.5 VA at 240 VAC N/A CAD Icon (for items table)
NFB24-SR N/A minimum 90 in·lbminimum 10 N·m N/A 2-10 VDC N/A 95 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 3.5 W, 2.5 W N/A 6 VA (class 2 power source) N/A CAD Icon (for items table)
1 - 25 of 40 | Results Per Page | View | Unit of Measure
1 2