Part Number

Torque

Control Input

Running Time (Motor)

Power Supply

Power Consumption

Transformer Sizing

CAD

N/A minimum 180 in·lbminimum 20 N·m N/A On/Off N/A < 75 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 5 W, 2.5 W / heater 25 W N/A 7.5 VA (class 2 power source) / heater 25 VA N/A CAD Icon (for items table)
N/A minimum 180 in·lbminimum 20 N·m N/A MFT N/A 150 seconds (default), variable (70 to 220 seconds) N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 7.5 W, 3 W / heater 25 W N/A 10 VA (class 2 power source) / heater 25 VA N/A CAD Icon (for items table)
N/A minimum 180 in·lbminimum 20 N·m N/A 0-135 Ω N/A 150 seconds (default), variable (70 to 220 seconds) N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 7.5 W, 3 W / heater 25 W N/A 10 VA (class 2 power source) / heater 25 VA N/A CAD Icon (for items table)
N/A minimum 180 in·lbminimum 20 N·m N/A MFT N/A 150 seconds (default), variable (70 to 220 seconds) N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 7.5 W, 3 W / heater 25 W N/A 10 VA (class 2 power source) / heater 25 VA N/A CAD Icon (for items table)
N/A minimum 180 in·lbminimum 20 N·m N/A On/Off N/A < 75 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 5 W, 2.5 W / heater 25 W N/A 7.5 VA (class 2 power source) / heater 25 VA N/A CAD Icon (for items table)
N/A minimum 180 in·lbminimum 20 N·m N/A 2-10 VDC N/A 95 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 5.5 W, 3 W / heater 25 W N/A 8.5 VA (class 2 power source) / heater 25 VA N/A CAD Icon (for items table)
N/A minimum 180 in·lbminimum 20 N·m N/A 2-10 VDC N/A 95 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 5.5 W, 3 W / heater 25 W N/A 8.5 VA (class 2 power source) / heater 25 VA N/A CAD Icon (for items table)
N/A minimum 180 in·lbminimum 20 N·m N/A On/Off N/A < 75 seconds N/A 24…240 VAC +10% / -20%, 50/60 Hz, 24…125 VDC ±10% N/A 7 W, 3.5 W / heater 25 W N/A 7 VA at 24 VAC (class 2 power source), 8.5 VA at 120 VAC, 18 VA at 240 VAC / heater 25 VA N/A CAD Icon (for items table)
N/A minimum 180 in·lbminimum 20 N·m N/A On/Off N/A < 75 seconds N/A 24…240 VAC +10% / -20%, 50/60 Hz, 24…125 VDC ±10% N/A 7 W, 3.5 W / heater 25 W N/A 7 VA at 24 VAC (class 2 power source), 8.5 VA at 120 VAC, 18 VA at 240 VAC / heater 25 VA N/A CAD Icon (for items table)
N/A 180 in·lb20 N·m N/A On/Off N/A < 75 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 5 W, 2.5 W N/A 7.5 VA (class 2 power source) N/A CAD Icon (for items table)
N/A 180 in·lb20 N·m N/A MFT N/A 70-220 (150) seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 7.5 W, 3 W N/A 10 VA (class 2 power source) N/A CAD Icon (for items table)
N/A 180 in·lb20 N·m N/A 0-135 Ω N/A 70-220 (150) seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 7.5 W, 3 W N/A 10 VA (class 2 power source) N/A CAD Icon (for items table)
N/A 180 in·lb20 N·m N/A MFT N/A 70-220 (150) seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 7.5 W, 3 W N/A 10 VA (class 2 power source) N/A CAD Icon (for items table)
N/A 180 in·lb20 N·m N/A On/Off N/A < 75 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 5 W, 2.5 W N/A 7.5 VA (class 2 power source) N/A CAD Icon (for items table)
N/A 180 in·lb20 N·m N/A 2-10 VDC N/A 95 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 5.5 W, 3 W N/A 8.5 VA (class 2 power source) N/A CAD Icon (for items table)
N/A 180 in·lb20 N·m N/A 2-10 VDC N/A 95 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 5.5 W, 3 W N/A 8.5 VA (class 2 power source) N/A CAD Icon (for items table)
N/A 180 in·lb20 N·m N/A On/Off N/A < 75 seconds N/A 24…240 VAC +10% / -20%, 50/60 Hz, 24…125 VDC ±10% N/A 7 W, 3.5 W N/A 7 VA at 24 VAC (class 2 power source), 8.5 VA at 120 VAC, 18 VA at 240 VAC N/A CAD Icon (for items table)
N/A 180 in·lb20 N·m N/A On/Off N/A < 75 seconds N/A 24…240 VAC +10% / -20%, 50/60 Hz, 24…125 VDC ±10% N/A 7 W, 3.5 W N/A 7 VA at 24 VAC (class 2 power source), 8.5 VA at 120 VAC, 18 VA at 240 VAC N/A CAD Icon (for items table)
N/A minimum 180 in·lbminimum 20 N·m N/A On/Off N/A < 75 seconds N/A 24…240 VAC +10% / -20%, 50/60 Hz, 24…125 VDC ±10% N/A 7 W, 3.5 W N/A 7 VA at 24 VAC (class 2 power source), 8.5 VA at 120 VAC, 18 VA at 240 VAC N/A CAD Icon (for items table)
N/A minimum 180 in·lbminimum 20 N·m N/A On/Off N/A < 75 seconds N/A 24…240 VAC +10% / -20%, 50/60 Hz, 24…125 VDC ±10% N/A 7 W, 3.5 W N/A 7 VA at 24 VAC (class 2 power source), 8.5 VA at 120 VAC, 18 VA at 240 VAC N/A CAD Icon (for items table)
N/A minimum 180 in·lbminimum 20 N·m N/A MFT N/A 150 seconds (default), variable (70 to 220 seconds) N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 7.5 W, 3 W N/A 10 VA (class 2 power source) N/A CAD Icon (for items table)
N/A minimum 180 in·lbminimum 20 N·m N/A MFT N/A 150 seconds (default), variable (70 to 220 seconds) N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 7.5 W, 3 W N/A 10 VA (class 2 power source) N/A CAD Icon (for items table)
N/A minimum 180 in·lbminimum 20 N·m N/A MFT N/A 150 seconds (default), variable (70 to 220 seconds) N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 7.5 W, 3 W N/A 10 VA (class 2 power source) N/A CAD Icon (for items table)
N/A minimum 180 in·lbminimum 20 N·m N/A MFT N/A 150 seconds (default), variable (70 to 220 seconds) N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 7.5 W, 3 W N/A 10 VA (class 2 power source) N/A CAD Icon (for items table)
N/A minimum 180 in·lbminimum 20 N·m N/A 0-135 Ω N/A 150 seconds (default), variable (70 to 220 seconds) N/A 24 VAC ±20%, 50/60 Hz, 24 VDC +20% / -10% N/A 7.5 W, 3 W N/A 10 VA (class 2 power source) N/A CAD Icon (for items table)