Part Number

Minimum Torque

Control Type

Running Time (Motor)

Running Time (Spring)

Power Supply

Power Consumption

Revit

CAD

FSAF120 US N/A 15 N·m133 lb·in N/A On/Off N/A 75 seconds constant, independent of load N/A < 20 seconds N/A 120 VAC ±10%, 50/60 Hz N/A Run 9.5W 11VA .1A, Hold 3.5W 6VA .05A N/A Revit Icon (for items table) N/A CAD Icon (for items table)
FSAF120-S US N/A 15 N·m133 lb·in N/A On/Off N/A 75 seconds constant, independent of load N/A < 20 seconds N/A 120 VAC ±10%, 50/60 Hz N/A Run 9.5W 11VA .1A, Hold 3.5W 6VA .05A N/A Revit Icon (for items table) N/A CAD Icon (for items table)
FSAF230 US N/A 15 N·m133 lb·in N/A On/Off N/A 75 seconds constant, independent of load N/A < 20 seconds N/A 230 VAC ±14%, 50/60 Hz N/A Run 11 W, 12 VA, 0.7 A, Hold 3.5 W 6 VA .03 A N/A Revit Icon (for items table) N/A CAD Icon (for items table)
FSAF230-S US N/A 15 N·m133 lb·in N/A On/Off N/A 75 seconds constant, independent of load N/A < 20 seconds N/A 230 VAC ±14%, 50/60 Hz N/A Run 11 W, 12 VA, 0.7 A, Hold 3.5 W 6 VA .03 A N/A Revit Icon (for items table) N/A CAD Icon (for items table)
FSAF24 US N/A 15 N·m133 lb·in N/A On/Off N/A 75 seconds constant, independent of load N/A < 20 seconds N/A 24 VAC ±20%, 24 VDC -10% +20% N/A Run 7.5 W 10 VA .4 A, Hold 2 W 4 VA .15 A N/A Revit Icon (for items table) N/A CAD Icon (for items table)
FSAF24-BAL US N/A 15 N·m133 lb·in N/A 3 position N/A 75 seconds constant, independent of load N/A < 20 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC ±10% N/A Run 9.5 VA 6.5 W. DC 6 W. Hold 5 VA 3 W DC 3 W N/A Revit Icon (for items table) N/A CAD Icon (for items table)
FSAF24-BAL-S US N/A 15 N·m133 lb·in N/A 3 position N/A 75 seconds constant, independent of load N/A < 20 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC ±10% N/A Run 9.5 VA 6.5 W. DC 6 W. Hold 5 VA 3 W DC 3 W N/A Revit Icon (for items table) N/A CAD Icon (for items table)
FSAF24-S US N/A 15 N·m133 lb·in N/A On/Off N/A 75 seconds constant, independent of load N/A < 20 seconds N/A 24 VAC ±20%, 24 VDC -10% +20% N/A Run 7.5 W 10 VA .4 A, Hold 2 W 4 VA .15 A N/A Revit Icon (for items table) N/A CAD Icon (for items table)
FSAF24-SR US N/A 15 N·m133 lb·in N/A Modulating N/A 75 seconds constant, independent of load N/A < 20 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC ±10% N/A Run 11 VA, 7 W, Hold 5 VA 3 W N/A Revit Icon (for items table) N/A CAD Icon (for items table)
FSAF24-SR-S US N/A 15 N·m133 lb·in N/A Modulating N/A 75 seconds constant, independent of load N/A < 20 seconds N/A 24 VAC ±20%, 50/60 Hz, 24 VDC ±10% N/A Run 11 VA, 7 W, Hold 5 VA 3 W N/A Revit Icon (for items table) N/A CAD Icon (for items table)
FSAF120A N/A 20 N·m180 lb·in N/A On/Off N/A < 25 sec N/A 25 seconds N/A 120 V N/A 28 W, 38 VA ,10 W, 24 VA, End stop 54 VA, 0.5 A slow blow fuse * N/A Revit Icon (for items table) N/A CAD Icon (for items table)
FSAF230A N/A 20 N·m180 lb·in N/A On/Off N/A < 25 sec N/A 25 seconds N/A 230V N/A 29 W, 37 VA ,10 W, 19 VA, End stop 54 VA, 0.25 A slow blow fuse * N/A Revit Icon (for items table) N/A CAD Icon (for items table)
FSAF24A N/A 20 N·m180 lb·in N/A On/Off N/A < 25 sec N/A 25 seconds N/A 24V N/A 23 W, 32 VA ,6.5 W, 11 VA, End stop 47 VA, 2 A slow blow fuse * N/A Revit Icon (for items table) N/A CAD Icon (for items table)
FSAF120A-S N/A 20 N·m180 lb·in N/A On/Off N/A < 25 sec N/A 25 seconds N/A 120 V N/A 28 W, 38 VA ,10 W, 24 VA, End stop 54 VA, 0.5 A slow blow fuse * N/A Revit Icon (for items table) N/A CAD Icon (for items table)
FSAF230A-S N/A 20 N·m180 lb·in N/A On/Off N/A < 25 sec N/A 25 seconds N/A 230V N/A 29 W, 37 VA ,10 W, 19 VA, End stop 54 VA, 0.25 A slow blow fuse * N/A Revit Icon (for items table) N/A CAD Icon (for items table)
FSAF24A-S N/A 20 N·m180 lb·in N/A On/Off N/A < 25 sec N/A 25 seconds N/A 24V N/A 23 W, 32 VA ,6.5 W, 11 VA, End stop 47 VA, 2 A slow blow fuse * N/A Revit Icon (for items table) N/A CAD Icon (for items table)